Our Dixell Controller Range
- Temperature Controllers: Designed to regulate and monitor temperatures in refrigeration units, display cases, cold rooms, and freezers, ensuring consistent cooling and preserving product quality.
- Humidity Controllers: Maintain precise humidity levels in climate-controlled environments, ideal for applications like cold storage, greenhouses, and data centers.
- Defrost Controllers: Automatically manage defrost cycles to prevent ice build-up in refrigeration systems, reducing maintenance needs and enhancing system efficiency.
- Multifunction Controllers: Advanced controllers capable of managing multiple parameters, such as temperature, humidity, and defrost cycles, from a single unit.
Refrigeration Controllers
Efficiency, connectivity and saving for refrigeration.
E Class
Chiller Controllers ( IC Series)
Prime Controllers
Dixell Monitoring Systems
Our innovative cold chain solutions give you actionable insights to help ensure food safety, improve efficiency and protect profits.
X Web Monitoring Solutions
Dixell Programmable Controllers
The most advanced technology in connectivity and processing speed
IPG200 A01
Dixell Cold Storage and Maturing Rooms Controllers
Overview
Models XLR130 and XLR170, 210x230mm format, are microprocessor based controllers suitable for applications on medium or low temperature refrigerating units. They are provided with four (XLR130) or six (XLR170) relay outputs to control compressor, defrost – which can be either electrical or hot gas (XLR170) – the evaporator fans (XLR170), the lights, the alarm and an auxiliary output. They are also provided with three NTC or PTC probe inputs, one for temperature control, one to control the defrost end temperature of the evaporator and the third, optional, for the display. There are two digital inputs (free contact) for the door switch and configurable by parameter.
The standard TTL output allows the user to connect, by means of a TTL/RS485 external module, a ModBUS-RTU compatible monitoring system and to programme the parameter list with the “Hot Key”.
Each model in the XLR100 can be provided with a Real Time Clock which allows programming of up to eight daily defrost cycles, divided into holidays and workdays. A “Day and Night” function with two different set points is fitted for energy saving.
Specifications
ADVANCED MULTIFUNCTION CONTROLLER FOR N.T., M.T. AND L.T. COLD ROOMS
Generals
Power supply: 24, 110, 230Vac
Display: n° digits: ± 3 d.p.
Keyboard: push buttons: 8
Probe inputs
Thermostat: NTC/PTC
Display: NTC/PTC
Others
Hot Key/Prog Tool Kit output: present
Serial output: RS485 optional
Buzzer: present
Real time clock: optional
Digital inputs
Alarm, block alarm, pressure switch, start defrost, energy saving, ON/OFF, AUX, holiday: configurable
Door switch: present
Relay outputs
Compressor: 20A
Light: 16A
AUX: 20A
Alarm: 8A
Features
- Advanced multifunction refrigeration controllers suitable for both heating and cooling
- Temperature control can be performed on probe 1, probe 2 or by the difference between probe 1 and 2
- Complete compressor and defrost management
- Direct line power supply 230 (110)Vac. – no external transformer required
- Maximum and minimum temperature recording
- Instant visibility of machine status via display icons, clear alarm signals thanks to the front lid
- Fast and easy wiring
- Designed to be wall or panel mounted
- Standard communication protocol ModBUS-RTU
- Hot key or Prog tool kit connector for a quick and easy programming
- 10VA max power absorption
- Display with red LED (30,5mm high) and 11 icons
Dixell Blast Chillers Controllers
Overview
Specifications
- The CYCLES: Cy1, Cy2, Cy3, Cy4 are pre-set according to the most common cycles used in food safety applications; the user can select one of them according to his own requirements and modify it as he wants.
- Any cycle can be manually terminated before the normal.
- Any cycle can use the insert probes (up to 3), they measure the internal temperature of the product.
- During the Cycle there are no defrosts and the fans are always on, a defrost cycle can be done before any freezing cycle.
- The cycle is divided up to 3 phases completely configurable by the user.
- Each instrument is provided with an output for remote display XR REP, which shows the temperature of cabinets or goods.
- The XB570L controller is provided with internal real-time clock and can be connected to the XB07PR printer. This means that a report, which includes all the main features of cycle, can be printed: start and end of the cycle, length of the cycle, logging of the temperature of the cabinet and goods.
- Design to comply with the rules concerning preparation and chilling of foodstuffs (HACCP)
- Four configurable cycles: pre-set according to the most common food – safety applications: soft chill, hard chill and freezing
- Output for remote display to monitor the core temperature of goods
- Internal real time clock
- Printer output (XB07PR) for temperature and blast chiller cycles reports
- All different phases monitored and shown on the display
- Ultra violet sterilization cycle management
- Standard communication protocol ModBUS-RTU
- Hot Key 128 or Prog tool kit connector for a quick and easy programming
- 5VA max power absorption
- Dual display with red LED (8,0mm high) and yellow LED (5,6mm high) and 14 icons
Features
- Compact design
- Coil windings are insulated to provide shock and vibration protectiion
- Interchangeable housings
- Designed to provide weather protection if used with connector (NEMA 2)
Dixell Temperature, Pressure and Humidity Probes
Overview
- Temperature: PTC probes, NTC probes, PT1000 probes, PRODUCT probes, PT100 thermo-resistors and TC thermocouples
- Temperature / Humidity: for HVAC/R (ideal for residential/industrial conditioning and refrigeration applications). Wall mounting (503 box dim. compatible), DEW-POINT and RS485
- Humidity: suitable for all those applications where it is necessary to detect and control humidity
- Pressure: pressure transducers and radiometric pressure transducers
Specifications
NTC Probes
The probes with NTC thermistor are designed for applications where high accuracy and short responce time is important. The probe passes several tests, this is why we guarantee a very hith reliability. The temperature range is -40 ÷ 110°C (-40 ÷ 230°F).
PTC Probes
The probes with PTC thermistor are designed for both cooling and heating applications.The temperature range is -50 ÷ 150°C (-58 ÷ 302°F).
Humidity Probes
XH10P and XH20P humidity probes are suitable for all those applications where it is necessary to detect and control humidity. Such applications are: refrigeration, drying processes etc.
Features
- Compact design
- Coil windings are insulated to provide shock and vibration protectiion
- Interchangeable housings
- Designed to provide weather protection if used with connector (NEMA 2)
Dixell Electronic Accessories
Overview
Meeting electronic world needs, Dixell offers global and complete solutions, not only about controllers, but which includes a wide series of useful accessories. They make the use of every regulator very simple, fast and safe.
Among the most important: modems, (for systems and programmable controllers), programming keys / tools, serial interface, remote display, connections, printers, adapters, filters, transformers, gaskets, protections and light switches.
Specifications
WM14D
Energy analyser, three-phase, with RS485 output.
Power supply: 90÷260Vac
Dimensions: 107,5x90x63mm
Mounting: DIN Rail and wall mounting
Modems and Cables
Systems and programmable controllers are available with analog/GSM modems and wirings
TC-35 kit
GSM modem kit containing the modem, the power supply unit, the transmitting antenna with the relevant cable and the connection to controlling system
For: XWEB and iPro
XWEB modem
Analogue serial modem, PDA compatible, 56kbps
For: XWEB and iPro
Ethernet patch cable, 3m
For: XWEB and iPro
Programming
A series of useful accessories like hot key, keyboard and complete tool are available for controller programming.
Hotkey – Key for a quick and easy Dixell’s controllers programming
Dimensions: 0.8x16x46mm
KB1-PRG: 6 keys programming keyboard
For: XEV, XJA-XJP-XJR
CAM/KB11: KB1-PRG keyboard cable, 1m
WIZMATE Prog- tool kit
Programming kit made up of CD and DIN Rail module (PROG-TOOL) with connections for Hot Key and RS485 for Dixell instruments; it allows the user to connect controllers to a PC running Windows 2000/XP OS. The CD-rom includes: WIZMATE software (to program an instrument or a Hot Key). The Kit includes: the CAB/PTK2 wire for DIN module instrument connection, the CAB/PTK485 wire for DIN module RS485 (built-in) instrument connection, the CAB/SW9-9 wire for PC connections.
Programming
Serial interfaces are available to make the conversion of the TTL output into a RS485 signal in order to realize a connection with controlling and supervising system.
XJ485CX
The serial interface converts the TTL output into a RS485 signal in order to connect the controller to the controlling and supervising system.
Dimensions: 1,6x16x46mm.
Multipolar connector included: 0,2m
Remote display
The remote display and its connections let you to read at distance the controller temperature.
X-REP:
Remote display for temperature reading to be used with compatible Dixell’s controllers.
Display: n° digits +/- 3 d.p.
Power supply: from the controller
CAB52F: Cable for X-REP, 2m
To use with: XJA, XJP, PRIME CX
Connections
A complete series of connectors for an easier and quicker mounting, especially in conditioning field.
CW-15 Kit: Female connectors 12-14 pins with wires 1,5m
Transformers
A series of transformers are available to adapt the main line of the controllers to a low voltage input.
TF10D: This model with 10VA of power is available in the following versions: 230/24Vac and 110/24Vac – 2 DIN Rail format
TF20D: This model with 20VA of power is available in the following versions: 230/24Vac and 110/24Vac – 2 DIN Rail format
Light Switches
Features
- Compact design
- Coil windings are insulated to provide shock and vibration protectiion
- Interchangeable housings
- Designed to provide weather protection if used with connector (NEMA 2)